Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 176402 E

PWXEDM
176402
E

CICS Shutdown (Immediate) requested due to Initialization error/s
During CICS/VSAM ECCR initialization, one or more fatal errors occurred. To prevent change data loss, the CICS region must be shut down.
PowerExchange issues a request to shut down CICS.
To determine the cause of the errors, examine the CICS job log, MVS SYSLOG data set, and PowerExchange message log. Then correct the problem and start the CICS/VSAM ECCR again.

0 COMMENTS

We’d like to hear from you!