PWXEDM 176419 E

PWXEDM
176419
E

SHOWCAT for
data_set_name
{CLUSTER | DATA} failed with RC=
return_code
When PowerExchange tried to get key details for the base data set for a VSAM path, the VSAM SHOWCAT macro failed with specified return code on the CLUSTER or DATA component entry in the VSAM catalog.
PowerExchange terminates the Open request for the VSAM file and closes the file.
Verify that the VSAM path and the associated CLUSTER or DATA component are correctly defined. If the problem persists, contact Informatica Global Customer Support.