Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172603 E

PWXEDM
172603
E

VSAM
macro
failed RC
return_code
and FDBK
code
for DDNAME
ddname
A PowerExchange Logger for z/OS internal VSAM macro operation failed. This message includes the return code and feedback code that was captured by the SHOWCB macro.
If the VSAM operation ran against the JOURNAL or TRACE file, the PowerExchange Logger suspends VSAM file processing. If the operation was for a DEFINE_LOG command, the PowerExchange Logger ends the command. In other situations, the PowerExchange Logger ends.
To determine the cause of the error, check the appropriate VSAM manual for an explanation of the return code and feedback code. Then correct the problem and run the job again.