The PowerExchange Logger for z/OS attempted to send a quiesce (QUIESCL) or resume (RESUMEL) command to the Post‑Log Merge task, but the PUT operation to the cross-system coupling facility (XCF) failed.
This message text includes the PowerExchange Logger ID, the type of command, the return code, and the reason code. The return code and reason code are generated in EDMXXCF and are not currently documented.
Processing continues.
If a quiesce command was issued, the PowerExchange Logger is not quiesced. The Post‑Log Merge task continues to merge data from this PowerExchange Logger, even if no new user data is being logged.
If a resume command was issued, the PowerExchange Logger remains in the quiesced state. ECCRs that try to connect to the PowerExchange Logger are delayed because they will not get a response to a signon request until the problem is resolved.
Determine the reason for the failure in the PUT operation. Use the appropriate operating system documentation. Also, review any other messages that have been issued in conjunction with this problem or that have been issued by the corresponding Post‑Log Merge task. To resolve the problem, you might need to restart either the Post‑Log Merge task or PowerExchange Logger. If you cannot correct the problem, contact Informatica Global Customer Support.