Message Reference Volume 3

PWXEDM 177612I

PWXEDM
177612
I

{QW0306ES|WQALLRBA|last returned}
rba_or_lrsn
This message reports one of the following the RBA or LRSN values for a DB2 for z/OS log location that was returned to the QW0306ES or WQALLRBA module or that was last returned:
  • For QW0306ES, this value is the end-of-scope value that is returned by an IFI306 call.
  • For WQALLRBA, this value is the location of the first-requested log record for an IFI306 'F' call (f).
  • For
    last returned
    , this value is the location of the log record read just before the log record that is reported in the previous PWXEDM177611I message.
This message accompanies messages PWXEDM177611I and PWXEDM177613E and is related to the error reported in PWXEDM177613E.
After the DB2 ECCR generates message PWXEDM177613E, the ECCR abends.
For information about the related error, see PWXEDM177613E.