Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172656 E

PWXEDM
172656
E

Logger unable to process log truncation request for reason
reason_code
The PowerExchange Logger physical logger encountered an internal error while attempting to truncate the current active log. While processing the ARCHIVE_LOG command, the PowerExchange Logger physical logger routine received an internal request to force‑write the log buffer and to truncate the active log and switch to the next available active log data set.
This error might have been caused by an unrelated abend in the PowerExchange physical logger, a STOP MODE=FORCE command, or an abnormal subsystem termination. The
reason_code
can be one of the following values:
  • 04
    . The end of current active log operation failed.
  • 08
    . The new active log operation could not be determined.
The PowerExchange Logger stops processing the command.
To diagnose the error, look up the messages and abends that precede this message. If possible, correct the problem and run the job again. If the problem persists, collect all available information about the error and contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!