Logger unable to process log truncation request for reason
reason_code
The PowerExchange Logger physical logger encountered an internal error while attempting to truncate the current active log. While processing the ARCHIVE_LOG command, the PowerExchange Logger physical logger routine received an internal request to force‑write the log buffer and to truncate the active log and switch to the next available active log data set.
This error might have been caused by an unrelated abend in the PowerExchange physical logger, a STOP MODE=FORCE command, or an abnormal subsystem termination. The
reason_code
can be one of the following values:
04
. The end of current active log operation failed.
08
. The new active log operation could not be determined.
The PowerExchange Logger stops processing the command.
To diagnose the error, look up the messages and abends that precede this message. If possible, correct the problem and run the job again. If the problem persists, collect all available information about the error and contact Informatica Global Customer Support.