Message Reference Volume 3

PWXEDM 177543 E

PWXEDM
177543
E

DB2 Catalog tables are not DATA CAPTURE CHANGES.
During initialization, the DB2 for z/OS ECCR determined that one or more of the DB2 catalog tables that it uses does not have the required DATA CAPTURE CHANGES attribute. The ECCR uses the following catalog tables:
  • SYSIBM.SYSTABLES
  • SYSIBM.SYSCOLUMNS
  • SYSIBM.SYSTABLESPACE
  • SYSIBM.SYSFIELDS
  • SYSIBM.SYSCOPY.
Message PWXEDM177398E indicates which of these tables is missing the attribute.
The ECCR ends without processing any DB2 log data.
Set the DATA CAPTURE CHANGES attribute on the catalog tables that are missing the attribute. Then cold start or special start the ECCR. If you warm start the ECCR, it does not recognize the current status of the DB2 catalog tables and fails, even if the DB2 catalog tables were altered to add the DATA CAPTURE CHANGES attribute.