Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL5008
  3. DTL58001 to DTL62569
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175050
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177522 E

PWXEDM
177522
E

TCAPTABLESPACE ROW NOT FOUND IN CAPTURE DIRECTORY
The internal state of the DB2 ECCR capture directory tables is not correct.
This message is usually issued during an ECCR special start, when a DDL operation that deletes a tablespace occurs between the time the log record that is used for the special start is written and the time the special start is executed.
The DB2 ECCR abends.
Ensure that only the DB2 ECCR or capture directory utility updates the capture directory tables.
If you performed a special start, either try performing a cold start or retry the special start immediately after the point in the log where the error occurred. If this issue did not occur during a special start, or if you performed a special start and processed the DB2 log up to the current point in time, gather all ECCR job output, including the dump output, and then contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!