The specified PowerExchange Logger for z/OS command completed or failed with the specified return code and reason code. In the message text,
command
is one of the following values:
ARCHIVE_LOG
DEFINE
DEFINE_LOG
DEL_LOG
DISPLAY
END
PRINT
RESOLVE_INDOUBT
STOP
TRACE
If the return code and reason code are 0, command processing continues. Otherwise, command processing ends, even though PowerExchange Logger processing continues.
If the return code and reason code are 0, no response is required. If the return code and reason code are a non-zero value, check the JES2 log for previous messages from the PowerExchange Logger that pertain to the specified command.
If this message is for an ARCHIVE_LOG command, you must correct the problem that is preventing the PowerExchange Logger from performing the archive process normally. This problem might be related to space availability or catalog issues. After the problem is corrected, other waiting offload tasks have completed, and another active log is available, issue the ARCHIVE_LOG command again for the current active log. If you do not correct the error, the PowerExchange Logger will issue warning messages when available active log data space reaches critically low levels. A final message indicates that there is no active log. The PowerExchange Logger then stops processing until active log space is made available.