Hi, I'm Ask INFA!
What would you like to know?
ASK INFAPreview
Please to access Ask INFA.
This page is the closest match. If it�s the page you were looking for, you might want to bookmark it for future use.

Table of Contents

Search

  1. Informatica Intelligent Cloud Services Release Notes
  2. Administrator
  3. API Center
  4. API Manager
  5. API Portal
  6. Application Integration
  7. B2B Gateway
  8. B2B Partners Portal
  9. Business 360 Console
  10. CLAIRE GPT
  11. Cloud Data Integration for PowerCenter (CDI-PC)
  12. Data Accelerator for Azure
  13. Data Access Management
  14. Data Governance and Catalog
  15. Data Ingestion and Replication
  16. Data Integration
  17. Data Marketplace
  18. Data Profiling
  19. Data Quality
  20. Data Validation
  21. Human Tasks
  22. Integration Hub
  23. MDM - Customer 360 SaaS
  24. MDM - Product 360 SaaS
  25. MDM - Reference 360
  26. MDM - Supplier 360 SaaS
  27. Metadata Command Center
  28. Model Serve
  29. Monitor
  30. Multidomain MDM SaaS
  31. Operational Insights

Release Notes

Release Notes

Known issues

Known issues

The tables in this section describe known issues for CDI-PC. Not all monthly releases include known issues.

October 2024 known issues

Issue
Description
CDIPC-12805
In AIX, the creation of CDI-PC repository content in a CDI-PC domain using Kerberos authentication fails when attempting to create the content through the CDI-PC installer.
CDIPC-12127
After you migrate a domain to CDI-PC, the first scheduled purge run fails with the following error:
[2024-08-14 19:36:30,237 IST] [ERROR] [Purge_Metering_Data_Worker-Thread_1] [PurgeMeteringDataTask] [CloudConn_10204] Metered data purge failed for repository [RS_ALL_1056]. Error: [Text '' could not be parsed at index 0] [2024-08-14 19:36:30,239 IST] [ERROR] [Purge_Metering_Data_Worker-Thread_1] [PurgeMeteringDataTask] [CloudConn_10204] Metered data purge failed for repository [RS_CDC]. Error: [Text '' could not be parsed at index 0]
However, the purge runs after the first failure are successful.
CDIPC-12036
When creating the CDI-PC Repository Service using the installer, incorrect connection failure messages are intermittently logged in the CDI-PC log files.
CDIPC-11792
In AIX, after uninstalling CDI-PC server using the console mode, the directory structure doesn't get deleted.

July 2024 known issues

Issue
Description
WB-3928,
WB-3876
If a conversion task contains a mapping that was already converted into a Data Integration mapping, the conversion job fails if there is any change in the mapping parameters. You might observe one of the following errors:
403 Forbidden: Provide a parameter with following name and type
500 Internal Server Error: Unable to load object - You do not have sufficient privileges or permissions to access the requested asset
Workaround: Delete the assets with the same name from Data Integration conversion location and run the conversion task again.
WB-1605
When you re-assess a repository, the conversion status of the converted assets changes to
Pending
even if there is no change in the PowerCenter assets.

February 2024 known issues

Issue
Description
CDIPC-8242
Uninstalling CDI-PC removes all files and folders that you might have placed in the
<UID>/Informatica
directory. Ensure that you do not place any file or folder in the
<UID>/Informatica
directory.

December 2023 known issues

Issue
Description
CDIPC-8579
If you delete an entry from the SSL certificate of a Secure Agent or the CDI-PC domain, reloaded certificates don't become effective until you restart the corresponding Secure Agent or domain.

August 2023 known issues

Issue
Description
CDIPC-5353
If you disable the CDI-PC Integration Service, you might encounter errors when you try to enable it. The errors might be related to authorization or the
PMPassword
option.
Workaround: Restart the CDI-PC Integration Service.

0 COMMENTS

We’d like to hear from you!