CDIPC-11068
| One of the CDI-PC installer screens on migration,
Migration Prerequisites - Step 2 of 8 , displayed an incorrect message about the need for an Informatica domain to not be Kerberos authenticated.
|
CDIPC-10816
| The operating system fails with the following error when you run the
Pre-Installation (i10Pi) System Check Tool on Red Hat Enterprise Linux 9 hosts:
[Fail] Operating System: Operating system is RHEL 9.3 (Plow). Operating system version is 5.14.0-362.24.1.el9_3.x86_64. Install an operating system that is supported with the CDI-PC installation. Refer to the Informatica Product Availability Matrix (PAM) for platform support information.
|
CDIPC-10259
| If a domain name included non-EN characters, the domain update took longer than usual to complete.
|
CDIPC-10213
| In a multi-node domain update, the update did not complete if the master gateway node did not start after the update. Because the master gateway node identified when the update began must update and start before other nodes updated, the update did not progress.
|
CDIPC-10137
| If you update the domain name or port number after an update fails, the update fails when you retry the update.
Workaround: Change the domain details to what they were when you initiated the update on both the domain machine and in the domain details in
Informatica Intelligent Cloud Services . Then retry the update.
|
WB-4058
| When you created a
Connection Map configuration and ran a conversion task with the configuration, the Secure Agent uploaded the
Connection_Details.xls file to internal storage.
|
Issue
| Description
|
|---|---|
CDIPC-11028
| After you register a CDI-PC domain, if the domain contains more than the supported number of nodes and services, the domain moves to offline state with the following error:
Caused by: com.mysql.cj.jdbc.exceptions.MysqlDataTruncation: Data truncation: Data too long for column 'service_list' at row 1
at com.mysql.cj.jdbc.exceptions.SQLExceptionsMapping.translateException(SQLExceptionsMapping.java:104) at com.mysql.cj.jdbc.ClientPreparedStatement.executeInternal(ClientPreparedStatement.java:916) at com.mysql.cj.jdbc.ClientPreparedStatement.executeUpdateInternal(ClientPreparedStatement.java:1061) at com.mysql.cj.jdbc.ClientPreparedStatement.executeUpdateInternal(ClientPreparedStatement.java:1009) at com.mysql.cj.jdbc.ClientPreparedStatement.executeLargeUpdate(ClientPreparedStatement.java:1320) at com.mysql.cj.jdbc.ClientPreparedStatement.executeUpdate(ClientPreparedStatement.java:994) at com.mchange.v2.c3p0.impl.NewProxyPreparedStatement.executeUpdate(NewProxyPreparedStatement.java:1502)
|
CDIPC-10355
| The April 2024 update availability notification appeared 24 hours before the update was available.
|
CDIPC-8568
| If a domain is shut down and you deregister the domain before the domain status updates to offline, the status doesn't update to online when you start the domain.
|
CDIPC-10036
CDIPC-10369
WB-3747
| The Date format is not localized in the
New Version Alert pop-up dialog box,
Explore page, and
My Jobs page.
|
WB-3995
| If a converted mapping contains a Router transformation that has a default output group name in English, the mapping becomes invalid. This issue is applicable only for Japanese locale.
|
WB-3959
| If a converted mapping contains a parameterized source, the advanced properties for some of the source transformations are not displayed.
|
WB-3958
| If a mapping contains an Expression transformation, the string data type fields are updated to 0 during the conversion process and the expressions become invalid.
|
WB-3952
| When you convert a mapping with a parameterized source or target file name prefixed by $, the parameter names in Data Integration retain the $. This causes a validation error because $ is not supported in parameter names in Data Integration.
|
WB-3684
| Assessment result displays the count for Manuals assets incorrectly.
|
WB-3644
| When you convert a mapping and repoint to Amazon Redshift, a white space is added to the following properties in Target and Lookup transformations:
This causes the mapping to fail at runtime.
|
WB-3143
| Conversion jobs fail intermittently due to agent authentication failure. In addition, the job status for the failed job is not updated immediately.
|
Issue
| Description
|
|---|---|
WB-3673
| If a PostgreSQL mapping task contains duplicate
tableType keys in data object attributes, the conversion task fails.
|
WB-3533
| If a workflow contains same session instance name at different levels of the workflow, the conversion job fails.
|
WB-3518
| When you repoint from ODBC to native PostgreSQL, the value in the
Source Table Name property is not populated for the source transformation.
|
WB-3517
| If the
PC_PARAMETER_ZIP.zip file used in an assessment job contains empty files or other zip files inside it, the assessment job gets stuck.
|
WB-3495
| If a workflow contains a sorter transformation, the conversion of the workflow fails.
|
WB-3424
| If a session contains space in the DBDNAME property, the conversion job fails.
|
WB-3139
| If a workflow contains two or more sessions and one session name is a substring of another session name, the conversion of the workflow fails.
|
WB-3131
| If a repository contains multiple folders with the same parameters but uses a single parameter file to resolve these parameters, the conversion job incorrectly repoints the database.
|
WB-2335
| If the target table name in a session contains a dot (.), the session publishing fails.
|
Issue
| Description
|
|---|---|
CDIPC-10048
| In a multi-node domain, if the master gateway node changes when the domain appears offline because the Secure Agent stops, the domain status doesn't update to available when the Secure Agent starts.
|
CDIPC-9145
| If a JWT authentication token expires when a domain is shut down and the Secure Agent starts on a different port when the domain starts on a different master node, the domain appears offline in
Informatica Intelligent Cloud Services and you cannot reconcile the domain.
|
CDIPC-8691
| If you retry an update after it fails with an
InterruptedException error, the update generates an exception and fails.
|
CDIPC-8617
| If you update the port number of a domain that is in offline state, the
Edit domain details page doesn't reflect the updated port number.
|
CDIPC-7930
| The domain installer and some infasetup commands display sensitive information in plain text.
|
CDIPC-1840
| The installer doesn't block migration of the same PowerCenter domain if you migrate to a different directory.
|
WB-2511
| When an assessment job is in progress, the
Repository page do not automatically refresh the status and might display an incorrect status of the job.
|
Issue
| Description
|
|---|---|
CDIPC-5372
| You can't run tasks in a sub-organization that shares a Secure Agent with the parent organization. Tasks that use a shared Secure Agent fail with the following error:
Error in decrypting ciphertext for orgId: {} with legacy technique
|
CDIPC-8600
| You can't edit the details of a domain that goes into offline state because the domain is shut down.
|
Issue
| Description
|
|---|---|
CDIPC-8201
| If you run jobs when the upgrade to the November 2023 release is in progress, you might encounter the following error:
None of the agents in the agent group can handle the request. |
Issue
| Description
|
|---|---|
CDIPC-5515
| When you configure the domain configuration repository database through the i10Pi System Check tool, the prompt mentions secure communication parameters for the domain instead of secure database parameters.
|
CDIPC- 5226