Hi, I'm Ask INFA!
What would you like to know?
ASK INFAPreview
Please to access Ask INFA.

Table of Contents

Search

  1. Informatica Intelligent Cloud Services Release Notes
  2. Administrator
  3. API Center
  4. API Manager
  5. API Portal
  6. Application Integration
  7. B2B Gateway
  8. B2B Partners Portal
  9. Business 360 Console
  10. CLAIRE GPT
  11. Cloud Data Integration for PowerCenter (CDI-PC)
  12. Data Accelerator for Azure
  13. Data Access Management
  14. Data Governance and Catalog
  15. Data Ingestion and Replication
  16. Data Integration
  17. Data Marketplace
  18. Data Profiling
  19. Data Quality
  20. Data Validation
  21. Human Tasks
  22. Integration Hub
  23. MDM - Customer 360 SaaS
  24. MDM - Product 360 SaaS
  25. MDM - Reference 360
  26. MDM - Supplier 360 SaaS
  27. Metadata Command Center
  28. Model Serve
  29. Monitor
  30. Multidomain MDM SaaS
  31. Operational Insights

Release Notes

Release Notes

Db2 for zOS Database Ingestion

Db2 for zOS Database Ingestion

Fixed issues

The following table describes fixed issues:
Issue
Description
DBMI-20340, DBMI-20232
A resync request on a Db2 for z/OS source table might cause database ingestion and replication jobs to fail. The problem occurs because z/OS can't get the end-of-log RBA for the connection retry.
(October 2024)
DBMI-20186
Database ingestion and replication incremental load or combined load jobs that have the
Modify Column
schema drift option set to
Stop Job
fail after the precision of a Db2 for z/OS column with the DECIMAL data type changes because of an internal code change, not in response to a customer-initiated DDL change.
(October 2024)
DBMI-19172
Database ingestion and replication incremental load or combined load jobs that have Db2 for z/OS sources might fail with the following error message when the source pwx.cdcreader.ZOS.UOWManagerMarkerControl custom property is set to True and the readerLogCaptureProgressMarker and readerMinutesRestartAdvanceMarkers custom properties are set to positive numbers:
com.infa.rat.pwxdbmi.pwxcdc.intf.CDCReaderException: Previous sequence <sequence_value> is not less than current sequence <sequence_value>
(August 2024)
DBMI-18742
Database ingestion and replication incremental load or combined load jobs that have a Db2 for z/OS source columns with the LONG VARCHAR data type, which is no longer supported in current Db2 versions, fail with the following error:
DB2 z/OS source CDC: Insert, Update, Delete parse failed with <null>
With this fix, database ingestion and replication jobs support the LONG VARCHAR data type.
(August 2024)
DBMI-17174
Database ingestion and replication
incremental load jobs that have a Db2 for z/OS source fail repeatedly with the following error message:
[CDCPUB_10066] TRACE: [PwxCDCReaderRunHandler encountered error :Previous sequence <sequence_number> is not less than current sequence <sequence_number>. Caused by: Previous sequence <sequence_number> is not less than current sequence <sequence_number>
(May 2024)

0 COMMENTS

We’d like to hear from you!