Command Reference

Command Reference

DISPLAY SUBSYS Command

DISPLAY SUBSYS Command

Displays the status of the connection to the IMS external subsystem of the IMS synchronous ECCR.
You can also use this command to get the CRC value that was defined for the subsystem. The CRC value is required for issuing IMS external subsystem commands with the /SSR command.

Syntax

Use the following command syntax:
/DISPLAY SUBSYS
ssid
The
ssid
variable is the subsystem identifier for the IMS external subsystem for the IMS synchronous ECCR.

Example Output

The following example output is produced by this command for the IMS external subsystem that has the subsystem ID of I24A:
R 89,/DISPLAY SUBSYS I24A IEE600I REPLY TO 89 IS;/DISPLAY SUBSYS I24A DFS000I     SUBSYS   CRC REGID PROGRAM LTERM   STATUS EDMA DFS000I     I24A     3                         CONN   EDMA
The output shows that the connection to the external subsystem is active and that the CRC value is 3.