Hi, I'm Ask INFA!
What would you like to know?
ASK INFAPreview
Please to access Bolo.

Table of Contents

Search

  1. Preface
  2. Understanding PowerExchange for Siebel
  3. PowerExchange for Siebel Configuration
  4. Siebel Sources
  5. Application Source Qualifier for Siebel Sources
  6. Siebel Targets
  7. Siebel Business Service Transformation
  8. Siebel EIM Read Transformation
  9. Siebel EIM Load Transformation
  10. Siebel EIM Invoker Transformation
  11. Siebel Sessions
  12. Datatype Reference
  13. Error Messages
  14. Glossary

PowerExchange for Siebel User Guide for PowerCenter

PowerExchange for Siebel User Guide for PowerCenter

Configuring Application Connection for Siebel EIM Read and Load Transformations

Configuring Application Connection for Siebel EIM Read and Load Transformations

The Siebel EIM Read and Load transformations use the Siebel Database Connection application connection to connect to the Siebel database. When you configure an application connection for the Siebel EIM Read or Load transformation, you must specify the connection attributes for the Siebel database.
To configure an application connection for the Siebel EIM Read or Load transformations:
  1. In the Workflow Manager, click Connections > Application.
    The Application Connection Browser dialog box appears.
  2. Click New.
  3. Select Siebel Database Connection from the list.
  4. Click OK.
    The Connection Object Definition dialog box appears.
  5. Enter the connection parameters.
    The following table describes the connection object parameters:
    Connection Parameter
    Description
    User Name
    User name to connect to Siebel.
    Password
    Password for the user name.
    Connect String
    ODBC data source name.
    Use Informatica certified ODBC drivers for ODBC data source connection.
    Connection Retry Period
    Number of seconds the PowerCenter Integration Service attempts to reconnect to the database if the connection fails. If the PowerCenter Integration Service fails to connect to the database in the retry period, the session fails. If you set the connection retry period to 0, the PowerCenter Integration Service does not attempt to reconnect to the database if the connection fails. Default is 0.
    Table Name Prefix
    If required, configure the table name prefix to establish connection with the database. Default is Blank.
    Enter the name of the Siebel database schema as the table name prefix when Oracle is the target database.
    For more information about connection parameters, contact your Siebel system administrator.

0 COMMENTS

We’d like to hear from you!