Hi, I'm Bolo!
What would you like to know?
ASK BOLOPreview
Please to access Bolo.

Table of Contents

Search

  1. Preface
  2. Understanding PowerExchange for Siebel
  3. PowerExchange for Siebel Configuration
  4. Siebel Sources
  5. Application Source Qualifier for Siebel Sources
  6. Siebel Targets
  7. Siebel Business Service Transformation
  8. Siebel EIM Read Transformation
  9. Siebel EIM Load Transformation
  10. Siebel EIM Invoker Transformation
  11. Siebel Sessions
  12. Datatype Reference
  13. Error Messages
  14. Glossary

PowerExchange for Siebel User Guide for PowerCenter

PowerExchange for Siebel User Guide for PowerCenter

Creating a Siebel EIM Load Transformation

Creating a Siebel EIM Load Transformation

You can create a Siebel EIM Load transformation in the Transformation Developer or the Mapping Designer.
  1. Open the Transformation Developer.
    Or, open the Mapping Designer.
  2. Click Transformation > Create.
    The Create Transformation dialog box appears.
  3. Select Siebel EIM Load transformation from the list.
  4. Enter a name for the Siebel EIM Load transformation.
  5. Click Create.
    The wizard appears.
  6. Enter the connection parameters.
    The following table describes the connection parameters:
    Connection Parameter
    Description
    Transport
    Enter http or TCPIP. Default is TCPIP.
    Encryption
    Enter NONE or RSA. Default is NONE.
    Compression
    Enter NONE or zlib. Default is zlib.
    Siebel Server Host
    Siebel server host name.
    SCBroker Port
    Siebel Connection Broker port number.
    Enterprise Server
    Siebel Enterprise Server name.
    Application Object Manager
    Siebel application business object manager.
    User Name
    User name to connect to Siebel.
    Password
    Password to connect to Siebel.
    Encoding
    Encoding that the Designer uses to communicate with the Siebel server. By default, the Designer uses the UTF-8 encoding.
    For more information about the connection parameters, contact your Siebel system administrator.
  7. Click Connect to connect to Siebel.
  8. Click Next.
  9. To view the list of all EIM tables in Siebel, select EIM Tables in the Based on list.
    Or, to view a list of base tables and corresponding EIM tables in Siebel, select Base Tables in the Based on list.
  10. Optionally, enter a filter condition to view particular Siebel base or EIM tables that meet the filter condition.
    If the sort order of the database is case-sensitive, specify the EIM or base table name in uppercase letters.
  11. Click Show Objects.
    EIM tables appear if they are active in Siebel.
  12. Select a base table to select all the corresponding EIM tables that you want to import.
  13. Optionally, select an EIM table from the list of EIM tables.
    The Table Fields area displays information about the selected EIM table.
    If the LOV Bounded column is selected for a field, the Designer retrieves value for the LOV Type column.
  14. Click Next.
  15. Enter a name for the transformation.
    If you use the Create Transformation dialog box to create the transformation, the transformation name specified in the Create Transformation dialog box overwrites the transformation name specified in the wizard.
  16. Click Finish.
  17. Click Done.

0 COMMENTS

We’d like to hear from you!