PWX- 36135

PWX-
36135

ORAD
rac_member
: Redo log file
file_name
: File start position
position
is greater than file length
length
.
The start position of the specified Oracle redo log file is greater than actual file length. The file might be corrupt, or a file system error might have occurred.
The PowerExchange Express CDC for Oracle log reader tries to use the alternate log file that has the same sequence number. If this alternate log file does not exist, CDC processing ends.
Restore the log file. If you cannot restore the log file, rematerialize the target and cold start the CDC session.