44022
]

The PowerCenter Integration Service cannot run the update, delete, or data-driven update strategy because the IF_ROW_BATCH_ID and ROW_ID fields are not linked in the mapping.
When the Treat Source Row As property is set to update, delete, or data-driven and the IF_ROW_BATCH_ID and ROW_ID fields are not linked in the mapping, the PowerCenter Integration Service cannot run the update strategy.
Link the IF_ROW_BATCH_ID and ROW_ID fields in the mapping.